Tracer AN Series (50~100A) MPPT Solar Charge Controller

The Tracer-AN (50A-100A) series is the largest line of charge controllers in EPEVER's product lineup and can carry solar panels up to 5KW. For more power, users can use PAL-ADP-50N to connect max. 6 controllers are connected in parallel, the maximum system is 30KW. Multiple dry contact signals are designed for diverse applications.

Share

Relation product

 
 
Model Tracer6210AN Tracer5415AN Tracer6415AN Tracer8415AN Tracer10415AN Tracer5420AN Tracer6420AN Tracer8420AN Tracer10420AN
Nominal system voltage 12/24VDC/Auto 12/24/36/48VDC/Auto
Battery type Lead-acid (Sealed/Gel/Flooded)/Lithium (LiFePO4/Li(NiCoMn)O2)/User
Battery input voltage range 8V~32V 8V~68V 8V~68V 8V~68V 8V~68V 8V~68V 8V~68V 8V~68V 8V~68V
Rated charge current 60A 50A 60A 80A 100A 50A 60A 80A 100A
Rated charge power 750W/12V
1500W/24V
625W/12V
1250W/24V 1875W/36V
2500W/48V
750W/12V
1500W/24V 2250W/36V
3000W/48V
1000W/12V
2000W/24V
3000W/36V
4000W/48V
1250W/12V
2500W/24V 3750W/36V
5000W/48V
625W/12V
1250W/24V 1875W/36V
2500W/48V
750W/12V
1500W/24V 2250W/36V
3000W/48V
1000W/12V
2000W/24V 3000W/36V
4000W/48V
1250W/12V
2500W/24V 3750W/36V
5000W/48V
Max. conversion efficiency 98.00% 98.30% 98.60% 98.50% 98.60% 98.30% 98.10% 98.50% 98.50%
Tracking efficiency ≥99.5%
Max. PV open circuit voltage 100V(At minimum operating environment temperature)
92V(At 25℃ environment temperature )
150V(At minimum operating environment temperature)
138V(At minimum operating environment temperature)
200V(At minimum operating environment temperature)
180V(At minimum operating environment temperature)
MPP voltage range (Battery Voltage+2V)
~72V
(Battery Voltage +2V)~108V (Battery Voltage+2V)~144V
Equalization voltage Sealed:14.6V,Flooded:14.8V,User-defined:9-17V
Boost voltage Gel:14.2V,Sealed:14.4V,Flooded:14.6V,User-defined:9-17V
Float voltage Gel/Sealed/Flooded:13.8V,User-defined:9-17V
Low voltage reconnect voltage Gel/Sealed/Flooded:12.6V,User-defined:9-17V
Low voltage disconnect voltage Gel/Sealed/Flooded:11.1V,User-defined:9-17V
Self-consumption 98mA/12V;60mA/24V;50mA/36V;46mA/48V
Temperature compensation( for lead-acid battery) -3mV/℃/2V(Default)
Relative humidity 5% to 95% (N.C.)
Enclosure IP20
Communication interface RS485(5VDC/200mA, Two RJ45 ports in parallel)
Grounding Common negative
Operating temperature range `-25℃~+60℃(derating above 45℃)
Dimensions(LxWxH)(mm) 340×232×105.2 261×216×119 340×236×119 394×240×134 394×242×143 261×216×119 340×236×119 394×240×134 394×242×143
Net weight 3.5kg 3.5kg 4.5kg 6.1kg 7.4kg 3.5kg 4.5kg 6.1kg 7.4kg
1. The controller can't automatically identify system voltage if lithium batteries were connected.
2. The voltage point is for the 12V system, please *2 in 24V system, *3 in 36V system, *4 in 48V system.